Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

NaturaLED 15W 48" T8 4000K Glass LED Bulb, Ballast Bypass

SKU: 5955 | Ordering Code: LED15T8/FR18/840  | UPC: 844366059551

$7.09each
Add to Cart
Save to BulbTrack ?

Quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home.

In StockReady to ship

This item does not ship outside the US

Free ground shipping on orders over $99*

Options

Product Highlights

  • Estimated life of 45.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
Description

Lighting Facts Per Bulb

Brightness 1800 lumens
Estimated Yearly Energy Cost $1.81
Based on 3 hrs/day, 11¢/kWh
Cost depends on rates and use
Life
Based on 3 hrs/day45.7 years
Light Appearance
WarmCool
4000 K
Energy Used15 watts
  • DLC
    Listed

NaturaLED single-ended power ballast bypass T8 4000K cool white 15 watt glass LED lamps are noise-free and non flickering. Excellent color consistency and ideal for offices, schools, hospitals, hotels and other applications.  An ideal energy saving choice for existing linear fluorescent fixtures. Safe to use in fixtures where ambient temperature is between -4°F and 113°F. Can be used in lensed recessed troffers.

Line Driven - Ballast must be bypassed when present.

To be used with unshunted sockets only, such as Leviton # L13351-U.

 

  • Replacement for:
    • F32T8 32W
    • F32T8 30W
    • F32T8 28W
    • F32T8 25W
  • Perfect for applications with frequent "on/off" switching cycles, and buildings that desire to be mercury free
  • Power must be turned off at the fixture before replacing the lamp
  • Instant on, no flicker or buzz
  • Emits virtually no UV rays or IR
  • Suitable for damp locations
  • DLC Listed

 

Full Specs

Brand

NaturaLED

Model Number

LED15T8/FR18/840G1
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
15 Watts
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120-277
Base
The end (or ends) of the lamp that fits into the socket.
Medium Bipin
Wiring
Wiring configuration a bulb can work with. Can be single-ended, double-ended or both.
Single Ended
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
T-8
Bulb Color
The color of the light produced by a bulb
Cool White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
80
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
4000
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
1800
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Opaque
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
50000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
-4 to 113
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
325
Bulb Power Type
Defines how a lamp is powered, whether it needs a ballast or not, or can use either
Ballast Bypass
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
48
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
1
Nominal Length (ft)
The length to the nearest foot that linear bulbs or fixtures will fit.
4
Socket Type
Type of socket a linear lamp is compatible with, whether shunted, non-shunted or both.
Non Shunted

Manufacturer Warranty

5 year limited
DLC Listing
Approved by the DesignLights Consortium, a collaboration of utility companies and regional energy efficiency organizations. Approved products meet the consortium's standards for ensuring high-quality, energy-efficient lighting design. There are three categories, Standard, Premium and Horticultural, plus Luna for light-pollution minimization.
PLA66RVQEWNU Standard